Saturday, August 16, 2025

ECG Blog #492 — Confused by the Pacemaker


Today's patient is an older man with a permanent pacemaker that was placed ~1 year ago for complete AV Block. He presents to the ED (Emergency Department) at this time — for new CP (Chest Pain) that began earlier in the day, and which has still persisted. The patient was hemodynamically stable at the time the ECG in Figure-1 was recorded.


QUESTIONS:
  • How would you interpret the ECG in Figure-1?
  • Should the cath lab be activated?

Figure-1: The initial ECG in today's case.


My Thoughts on Today’s CASE:
We are told that today's patient has a pacemaker — and that he presents for new CP persisting over the course of a day. Questions that arise include the following:
  • Do we see evidence of this patient's pacemaker in ECG #1?  If so — Is the pacemaker working appropriately?
  • Can we assess the ECG of a patient with a pacemaker for ST-T wave changes of acute OMI? If so — Are there any worrisome findings in ECG #1?



ANSWERS: Can We Detect Acute OMI in a Paced Tracing? 
As seen in Figure-2 — Pacemaker spikes are present (within the small RED circles in leads V4,V5). Similar tiny spikes are intermittently seen in other leads.
  • At least in leads V4,V5 — we see these pacemaker spikes just before wide QRS complexes with a LBBB-like morphology — so the pacmaker appears to be appropriately capturing the ventricles at ~85/minute.
  • It is at least sometimes possible to assess a paced ECG for ST-T wave changes of acute ischemia. Such assessment is made more challenging by QRS widening of paced beats (and resultant altered ST-T wave morphology) — but there are times when we can see evidence of acute OMI on a completely paced tracing.
  • In such instances — application of Smith-Modified Sgarbossa Criteria help to identify abnormal ST-T wave findings despite complete pacing (See Pearl #4 in ECG Blog #282 for review of Smith-Modified Sgarbossa Criteria).

PEARL #1:
 Even more than applying Smith-Modified Sgarbossa Criteria — I favor assessing for acute ischemia in paced tracings by looking for ST-T wave changes that just should not be there! This should be readily evident in Figure-2:
  • There is no way that the 4+ mm of downsloping ST depression in lead V6 with terminal T wave positivity can be a "normal" finding (within the RED rectangle in Figure-2). If anything — we would expect secondary ST-T wave changes of LBBB or in a paced tracing to be oppositely directly to the predominantly negative QRS deflection in lead V6.
  • In the context of this clearly abnormal downsloping ST depression in lead V6 — the more subtle flattened ST depression in neighboring lead V5 (BLUE arrow in this lead) is also abnormal.
  • The next lead in Figure-2 to catch my "eye" — is lead V1 (within the BLUE rectangle) — as the relative amount of J-point ST elevation in this lead is clearly disproportionate to the modest size of the S wave in this lead (The relative amount of ST elevation in lead V1 does appear to satisfy the 25% criteria of Modified-Smith Sgarbossa Criteria outlined in ECG Blog #282).
  • Given the clearly abnormal ST elevation in lead V1 — I thought the J-point ST elevation in neighboring lead V2 was also abnormal. While not satisfying the 25% criterion of Smith-Modified Sgarbossa — the J-point in this V2 lead is angled sharply (BLUE arrow in V2) — rather than manifesting a smoother transition as is normally expected between J-point and ST segment (Note the much smoother transition between J-point and ST segment in neighboring leads V3,V4 that I interpreted as normal).

BOTTOM Line:
 While the ST-T wave changes I describe above for leads V2 and V5 in Figure-2 are admittedly subtle — in this older patient with new CP — the abnormally shaped and disproportionate amount of ST depression in lead V6, supported by the disproportionate amount of ST elevation in lead V1 — has to indicate acute OMI until proven otherwise!
  • PEARL #2: The presence of coved ST elevation in leads V1,V2 with clearly abnormal ST depression in leads V5,V6 is consistent with Precordial Swirl — which suggests a proximal LAD occlusion (See ECG Blog #380 for more on Precordial Swirl).
  • To address the question posed at the beginning of today's case: YES, the cath lab should be immediately activated given the history of new CP and the ECG findings in Figure-2.


Figure-2: I've labeled today's initial ECG.


The CASE Continues:
A prior tracing on today's patient was found. To facilitate comparison in Figure-3 — I've put this previous ECG from ~8 months earlier together with today's initial ECG.
  • Does availability of this prior ECG support your decision to activate the cath lab?

Figure-3: Comparison between today's initial ECG — and a previous ECG done ~8 months earlier.


Comparison with the Prior Tracing:
Availability of the prior ECG on today's patient removes all doubt about the need to activate the cath lab!
  • PEARL #3: The BEST way to hone your ECG interpretation skills — is to train your "eye" in recognizing subtle findings by follow-up comparison with subsequent tracings to see how more subtle findings on the original tracing evolved over time.
  • Lead-to-lead comparison between ECG #1 and ECG #2 in Figure-3 shows significant changes in virtually every lead!
  • Looking first at the 2 leads that made the diagnosis for us — it is easy to see how abnormal the ST-T waves in leads V5 and V1 of Figure-1 truly were!
  • Looking further at the more subtle changes in leads V2 and V5 that I highlighted above — we can confirm the validity of my observations on seeing that there was more ST elevation in lead V2 in ECG #1 than there was on the prior ECG — and the subtle, flattened ST depression in lead V5 of ECG #1 was not at all present on the prior ECG.
  • ST-T wave changes in other leads are present on comparison between the 2 tracings in Figure-3 — but those changes are not nearly as easy to detect — which confirms my PEARL #4 from today's case = It is usually more difficult to assess paced tracings for acute ischemia — but it is definitely not impossible.

CASE Conclusion:
The cath lab was activated. Cardiac cath revealed the following:
  • There was significant 3-vessel disease.
  • 90% distal stenosis of the LMain.
  • 50% mid-LAD stenosis.
  • 90% patent ostial stenosis of the LCx.
  • 50% mid-RCA stenosis.
The LMain narrowed area was successfully stented to the patent LAD. The patient did well in follow-up.

====================================

PEARL #5: Had I not been told — I may not have realized that today's patient had a pacemaker from the initial ECG shown in Figure-1. Pacemaker spikes are often difficult to detect for a number of reasons:
  • There could be pacemaker malfunction.
  • There could be signal interference and artifact and/or "noise".
  • Modern pacemakers increasingly use bipolar leads — and bipolar leads generate smaller spikes on ECG.
  • Filter settings are suboptimal. This is especially true when the low-pass filter is set below the standard value of 150 Hz. That said — even at 150 Hz, the percentage of patients whose pacemaker spikes will be visible on a standard ECG has been found to be far less than the percentage for detecting pacemaker spikes on ECG with a higher low-pass filter of 300 Hz (Sun et al — Chin Med J 132(5):534-541, 2019).

Regarding Filter Settings:
I suspect suboptimal Filter settings is the most common reason that pacemaker spikes are not readily seen on many tracings. All too often — filter settings are ignored
  • Different settings are typically used for monitoring when emphasis is placed on rhythm determination vs diagnostic mode, for which the focus is on interpreting 12-lead waveforms. 
  • Greater filtering is generally used in monitor mode, with a common setting between 0.5 Hz and 40 Hz. Doing so has the advantage of minimizing artifact and baseline wander that may affect rhythm interpretation. 
  • In contrast — a broader passband (typically from 0.05 Hz to 150 Hz) — is recommended for diagnostic mode, where more accurate ST segment analysis is essential.
  • Modern bipolar pacemakers generate smaller pacing spike amplitudes compared to older devices, making them harder to detect on the ECG. Awareness that the filter setting is important — especially if you find yourself hopelessly looking for spikes in a tracing of a patient thought to have a pacemaker.


==================================

Acknowledgment: My appreciation to 林柏志 (from Taiwan) for the case and this tracing.

==================================



 


 







2 comments:

  1. I’ve noticed inappropriate concordance in act as well but it was not mentioned in the article, is this because it is not considered an important finding in this lead?

    ReplyDelete
    Replies
    1. Thanks for your comment. The disproportionate ST depression in lead V6 (in which the QRS is predominantly negative) IS "inappropriate discordance". I am not in favor of the term "inappropriate discordance" — because there are circumstances when it can be misleading. For example, in pacemaker tracings — it can be VERY difficult at times to determine how much discordance is or is not "appropriate". The point I am emphasizing here is that there is NO WAY that the ST depression in lead V6 could possibly be "normal". THANKS again for your comment — :)

      Delete